Navigation image map
Contact Us Cart Site Map Manuals Quotes Products Home

CALIBRATION SERVICES AVAILABLE FROM NEWPORT

FACTORY & NIST CALIBRATIONS for INSTRUMENTS
Certificate of Conformance Sample Certification
Upon request, NEWPORT will certify that the product(s) shipped on the buyer’s purchase order are manufactured in accordance with all applicable instructions and specifications on published data sheets. Chemical, physical, electrical, and/or inspection test data are on file with us or with our suppliers for examination and indicate conformance with applicable specification requirements. NEWPORT Electronics, Inc. further certifies that all thermocouple base and noble metal materials conform to ANSI Limits of Error (ANSI Standard MC96.1).
This calibration is provided at no charge.  Please specify at the time of order to receive this certificate.

Model No.CAL-1

Certificate of Calibration Sample Certification
Upon request, NEWPORT will certify that product shipped (model number, serial number, and buyer’s purchase order number specified) has been calibrated to meet or exceed the published specifications. This calibration was performed using instrumentation and standards that are traceable to the United States National Institute of Standards and Technology (
NIST).
This calibration is provided at no charge.  Must be requested at the time of order.

Model No. CAL-2

NIST Traceable Certificate of Calibration with Test Data Sample Certification
Same as CAL-2, with the addition of actual tested data points along with NIST traceable test numbers.  A CAL-3 provides the same documentation as a CAL-1/CAL-2 and gives you discrete test points of data and NIST traceable test numbers.   Calibration has been performed in compliance with ISO 10012-1 and ISO9001 Section 4.11 and ANSI/NCSL Z540-1-1994. The test uncertainty ratio (T.U.R.) of this calibration is at least 4:1 unless otherwise stated.
Model No. CAL-3
Pricing: This calibration is $85. Must be requested at the time of order.

Certificate of Calibration Sample Certification
Same as CAL-3, Calibration traceable to NIST with 4 data points (3 humidity and 1 temperature) across the instrument’s range. A CAL-3-HU provides the same documentation as a CAL-3 and gives you discrete test points of data and NIST traceable test numbers.   Calibration has been performed in compliance with ISO 10012-1 and ISO9001 Section 4.11 and ANSI/NCSL Z540-1-1994. The test uncertainty ratio (T.U.R.) of this calibration is at least 4:1 unless otherwise stated.
Model No. CAL-3-HU

Pricing: This calibration is $135. Must be requested at the time of order.

Certificate of Calibration
Sample Certification
Same as CAL-3-H
U, but for dual channel units.  Calibration traceable to NIST with 4 data points (3 humidity and 1 temperature) across the instrument’s range, per channel . A CAL-3-H-DUAL provides the same documentation as a CAL-3 but there is one certificate for each channel.  The certificates give discrete test points of data and NIST traceable test numbers.   Calibration has been performed in compliance with ISO 10012-1 and ISO9001 Section 4.11 and ANSI/NCSL Z540-1-1994. The test uncertainty ratio (T.U.R.) of this calibration is at least 4:1 unless otherwise stated.
Model No. CAL-3-HU
-DUAL
Pricing: This calibration is $195. Must be requested at the time of order.


FACTORY & NIST CALIBRATIONS for SENSORS, WIRE & INSTRUMENTS
With calibration instrumentation conforming to MIL-STD-45662A, NEWPORT can calibrate individual products (both new and existing) or complete systems, with NIST traceability if required. Scheduled, periodic calibration of equipment is easily arranged as well.

Probes and instruments that may be calibrated at customer-specified temperatures:
  • Thermocouple and RTD probes (thermistor must be calibrated as a system with a meter and wire).
  • Thermocouple wire.
  • Probe/meter systems.
  • Meters/instrumentation.

Wire calibration requires cutting approximately 3' from the spool being tested, forming a bead and performing the calibrations. The tested wire will be sent along with the spool and certification.

NIST TRACEABLE CALIBRATION OF PROBES Sample Certification
Upon request NEWPORT certifies that the item has been calibrated and tested to meet or exceed the published specifications. This calibration and testing was performed using instrumentation and standards that are traceable to the National Institute of Standards and Technology. Calibration has been performed in compliance with ISO 10012-1 and ISO9001
, ANSI/NCSL Z540-1-1994, ANSI MC 96.1 and ASTM E 230.

To Order (Specify Calibration Level)
Probe Calibrations
Model No. CAL-1 CAL-3 CAL-4 CAL-5
T/C Probes $0 $110 $85 setup
+$35

per point
$15
RTD
Probes
0 $110 $85 setup +
$45 per point
-
System Calibration (probe and Meter)*
T/C &
Instrument
- $135 $150 setup +
$35 per point
-
RTD or Thermistor &
Instrument
- $135 $150 setup +
$45 per point
-
Probe must meet requirements based on calibration standards.
*Prices are for new instruments and subject to change without notice. For recalibration, call customer service for price. Charges vary depending on the instrument being calibrated.
Note: Because of the large selection of temperature probes, thermocouple wire and instrumentation NEWPORT offers, the pricing and calibration data points shown above are only an example and do not apply to every probe or system calibration. Contact NEWPORT’s Customer Service prior to returning any instrument for calibration service.
Ordering Example:
CAL-3-TC (factory selected points)
, designate this calibration level when NIST traceability is required on the thermocouple probe or probe/instrument system you are purchasing new or returning previously purchased equipment for calibration, $110 (probe only), $135 (probe with instrument).

CAL-4-TC (customer selected points)
, designate this calibration level when NIST traceability is required on the thermocouple probe or probe/instrument system you are purchasing new or returning previously purchased equipment for calibration $85 + $35 (probe only), $150 + $35 (probe with instrument).

   
FACTORY CALIBRATION OF PROBES
Available for Types J, K, T, E and N mineral insulated thermocouples: quick disconnect, transition junction, utility handle, and low-noise styles. Each probe certified at four temperature standards. Calibration card included "pre-stocked" with each probe.
Ordering Example:
1
, select the style of probe needed for your application within this section.
2, to receive a calibration report detailing the accuracy of your probe at the standard Temperature points shown add -CL5 to the end of the probe part number and add $15 to the probe price.
KQIN-14G-12-CL5, type K quick disconnect probe with molded connector, 1/4" diameter 12" long with 4 standard points of calibration, $42.

CAL-5 Standard Calibration Points
Thermocouple
Calibration


  Liquid
Nitrogen
Ice
Point
Boiling
Point
Tin
Melting
Zinc
Melting
T -320°F
(-195.8°C)
32°F
(0°C)
212°F
(100°C)
449°F
(231.9°C)
­
J, K, E, N ­ 32°F
(0°C)
212°F
(100°C)
449°F
(231.9°C)
787°F
(419.6°C)


hot point®
HOT POINT

NEWPORT's hot point® Thermocouple and RTD Calibrator Calibrates All Temperature Sensors to Within ±1.5ºF.
Model CL900A & CL900.

ice point®
ICE POINT
NEWPORT's ice point® is a highly accurate 0ºC Thermoelectric "Refrigerator" Used in the Calibration of Temperature Instruments. Model TRCIII.

Sitemap | Order Status | Careers | About Us | ISO 9001 | Worldwide Affiliates | Terms & Conditions