Features
Put any serial device on the IP network in minutes
Bridge RS-232/RS-485 to TCP/IP
Auto-negotiating 10/100 Ethernet half/full duplex
Built-in Web server and embedded TCP/IP stack
TCP, UDP, SNMP, SMTP, TFTP, ICMP, Telnet, DHCP, DNS, HTTP, and ARP
ModbusRTU to Modbus TCP/IP bridging

Email notifications and SNMP traps

TCP socket with command line interface
1-6 programmable I/O’s

Serial speed up to 460 Kb/s

Authentication and access restrictions
Firmware upgrade over Ethernet

Small enough to fit almost anywhere

Free COM port redirector
Free configuration software
Custom firmware/private labeling for OEM’s

EIT-D -  Industrial DIN Rail iServer EIT-W - Commercial Wall-Mount iServer EIT-PCB - Embedded iServer

   FCC-B  Made in Santa Ana, CA

NEWPORT PRODUCT INFO
•  MANUAL - PDF
•  SOFTWARE iConnect
•  SOFTWARE OPC SERVER
•  FIRMWARE UPGRADE
•  SPECS - PDF
  MECHANICAL SPECS
 REQUIRES ADOBE ACROBAT - HELP
Connect Anything to Ethernet and Internet
The 3rd Generation NEWPORT® iServer3G connects any Serial Device (RS-232, RS-485) to an Ethernet network or the Internet in minutes, including Serial Modbus to Modbus TCP/IP over Ethernet.

The iServer3G can send notifications by email, and has SNMP for remote management. NEWPORT offers custom firmware and private-labeling for OEM's.

The award-winning NEWPORT iServer is still the simplest, easiest, most economical way to put anything on the network, without writing a single line of code.

The new iServer is built on one of the fastest, highly featured microprocessor found in any device of this kind.

Getting started with the iServer is very simple and easy because it can take a dynamically assigned IP address from a DHCP server on your network. This DHCP client capability is a valuable and unique feature of the NEWPORT iServer that makes it extremely easy and simple to start using this device on almost any Ethernet network.

You can easily assign a static IP address to the iServer instead of a dynamic one, if necessary. The IP address can be assigned locally through its serial connection, as well as remotely over an Ethernet network via Telnet or a web browser, using its factory default IP address.

The NEWPORT iServer connects to an Ethernet Network with a standard RJ45 connector. Serial devices connect to the iServer with a standard DB-9 connector
.

The iServer can be used to make an existing Serial device a "node" on an Ethernet network with a unique IP address that's accessible from any authorized computer on the LAN, WAN, or Internet.

The iServer can instead be used to create a virtual tunnel on an Ethernet/Internet network simulating a local point-to-point serial connection between a serial device and a PC. This replaces dedicated point-to-point wiring limited to 50 feet on an RS-232 connection.


The NEWPORT iServer packages the Serial data in standard TCP/IP packets that can travel anywhere on the Ethernet LAN or over the Internet. The NEWPORT iServer is compatible with almost any device with a Serial interface such as: time clocks, security alarms, card-key access controllers, telecommunications equipment, vending machines, bar code readers, electric power meters, UPS systems, test & measurement instrumentation, PLC's, serial printers, cash registers, and many more.

You do not need to rewrite the firmware for your serial devices to work with the iServer, and in some cases might not need to change your application software. Your serial devices will function over the Ethernet network or the Internet as if they were connected directly to a PC. The COM port on the iServer simulates a local COM port on the PC.

The NEWPORT iServer is compatible with wireless Ethernet. In settings where wires of any kind are not possible, the EIT can be connected to a Wireless Ethernet Access Point enabling simple, economical wireless connectivity of Serial Devices.

With the NEWPORT iServer: A facilities manager can monitor electric power usage over the LAN from a desk anywhere in the facility, or from anywhere on the Internet with the proper passwords and authorization. A payroll clerk can download data from time clocks to a PC anywhere on a local area network, or anywhere in the world. A manufacturing technician can use a handheld computer with Wireless Ethernet connectivity to change settings on a process controller.

There are three versions available:

The wall-mount MicroServer model EIT-W for most commercial and IT applications, comes complete with full documentation, firmware, and AC universal power adapter.

NEWPORT offers a printed circuit board-level product, model EIT-PCB (powered by 5 Vdc) that OEM's can incorporate in their product to add embedded Ethernet/Internet connectivity to products with existing serial interface. (Contact the NEWPORT OEM Engineering Group.)

For industrial applications, NEWPORT offers the EIT-D, in polycarbonate enclosures that mounts on a DIN rail.

For OEM's, NEWPORT offers custom labeling as well as customized application specific firmware and design engineering.

NEWPORT iServer products are designed and manufactured in Santa Ana, California. NEWPORT provides generous technical support.

Specifications

Serial Interface
Interface:
RS-232, or RS-485 (2 and 4-wire), or TTL

Connector: DB-9 (male DTE) for RS-232; 8 position Terminal Block plug for RS-485
Serial Data Rates: 300 to 460.8 Kbps
Characters: 5,6,7 or 8 data bits
Parity: odd, even, or none
Stop Bits: 1 or 2
Flow Control: Hardware (RTS/CTS) and Software (Xon/Xoff)
Digital I/O’s: 1 to 6 programmable input/output lines, depending on model

Network Interface
Interface:
Fixed or auto-negotiating 10/100BASE-T half/full duplex Ethernet with auto MDI/MDIX
Connector:
RJ45

Protocols: TCP, UDP, SNMP, SMTP, TFTP, ICMP, DHCP, DNS, HTTP, ARP, Telnet, and Modbus TCP/IP
Compliant to Standard: IEEE 802.3

Indicators (LED's)
100BASE-T, Network Link/Activity, and Serial Transmit/Receive

Processor
CPU: ARM7, 72 MHz
Memory:
512 Kbyte Flash, 32 Kbyte SRAM
Management
Web server, Telnet login, Serial login, iConnect
Embedded Web Server
Serves dynamic Web pages and Java applets

General
Environmental

Operating Temperature: -40 to 85 °C (-40 to 185°F)
Storage Temperature: -40 to 100°C (-40 to 212°F)
iDRN-PS-1000


Power (for EIT-W)
Input: 5 Vdc @ 200 mA max.
Consumption: 1 W max.
Safety Qualified Universal ac Power Adapter included:
  Nominal Output: 5 Vdc @ 600 mA;
  Input: 100 to 240 Vac, 50/60Hz
Power Adapter Operating Temperature:
0º to 40ºC (32º to 104ºF)


ac Universal Power Adapter
Universal ac Power Adapter

Power (for EIT-D)
Input: 10 to 32 Vdc
Consumption: 2 W max.
DC Power supply sold separately: iDRN-PS-1000

Power (for EIT-PCB)
Input: 5 Vdc @ 200 mA max.
Consumption: 1 W max.


Packaging (for EIT-W)
Material:
ABS (ChiMei PA-757) with wall mount bracket
Dimensions:
27.4H x 66.0W x 93.1D mm (1.08 x 2.60 x 3.67 in)

Weight:
77g (0.17 lbs.)


Packaging (for EIT-D)
Material:
Polycarbonate case with DIN Rail mount
Dimensions:
90.2H x 25.1W x 115.0D mm (3.54 x .99 x 4.53 in)
Weight: 113g (0.25 lbs.)
iDRN PS-1000
iDRN-PS-1000 Switching Power Supply

Packaging (for EIT-PCB)
Material:
FR4
Board Surface area dimensions:
approximately 80 sq. mm (3 sq")
Weight: 14g (0.03 lbs.)


Software
Firmware upgrade from Ethernet
COM Port redirector (iPort)
Configuration Software utility (iConnect)
Compatible with Windows 9x/ME/NT/2000/XP software and related utilities


EIT-D with standard 35mm DIN rail mount

Mechanical Dimensions

EIT-W --  DOWNLOAD CAD FILES
WEB FORMAT
AUTOCAD 2000


EIT-D   --  DOWNLOAD CAD FILES



EIT-PCB  --  DOWNLOAD CAD FILES
WEB FORMAT
AUTOCAD 2000

 

Sitemap | Order Status | Careers | About Us | ISO 9001 | Worldwide Affiliates | Terms & Conditions
Copyright ©2012, NEWPORT Electronics, Inc. All rights reserved.